ANDREX FLEXIBLE METAL CONDUIT
NOMINAL CORE MATERIAL PREFIX ANDREX CORE CORE SINGLE LAYER MIN. BEND
SIZE 70/30 NICKEL STAINLESS TRADE INSIDE  OUTSIDE BRAID OUTSIDE RADIUS 
(INCHES) BRASS IRON STEEL SIZE DIAMETER DIAMETER DIAMETER BRAIDED
1/8 AC ACNI ACSS 8 .110-.125 .200-.210 .235-.250 3/4
9/64 AC ACNI ACSS 9 .135-.145 .220-.230 250-.265 1
5/32 AC ACNI ACSS 10 .150-.160 .235-.245 .275-.295 1-1/8
3/16 AC ACNI ACSS 12 .175.190 .260-.270 .305-.320 1-1/8
.190 AC ACNI ACSS 12.5 .185-.195 .270-.280 .315-.330 1-1/8
.210 AC ACNI ACSS 13.5 .205-.215 .290-.300 .325-.340 1-3/8
.226 AC ACNI ACSS 14.5 .221-.231 .306-.316 .335-.350 1-3/8
1/4 AC ACNI ACSS 16 .235-.250 .330-.340 .385-.400 1-3/8
9/32 AC ACNI ACSS 18 .285-.300 .380-.390 .435-.450 1-1/2
5/16 AC ACNI ACSS 20 .313-.328 .410-.420 .465-.480 1-3/4
3/8 AC ACNI ACSS 24 .360-.375 .456-.466 .510-.525 2
7/16 AC ACNI ACSS 28 .425-.440 .520-.530 .575-.590 2-1/8
1/2 AC ACNI ACSS 32 .485-.500 .580-.590 .645-.660 2-1/4
5/8 AC ACNI ACSS 40 .610-.625 .705-.715 .780-.795 2-3/8
3/4 AC ACNI ACSS 48 .735-.750 .835-.845 .905-.920 2-1/2
1 AC - - 64 .985-1.000 1.130-1.140 1.210-1.225 3-3/4
1 1/4 AC - - 80 1.235-1.250 1.385-1.400 1.445-1.465 4-3/4
1 1/2 AC - - 96 1.485-1.500 1.662-1.677 1.715-1.735 5-1/2
2 AC - - 128 1.985-2.000 2.125-2.140 2.190-2.205 12
 
hose diagram
Feel free to download our spec sheets below,
but always contact us to insure you have the newest data.

CORE CORE SEAM BRAID
TYPE MATERIAL MATERIAL MATERIALS
AC BRASS ALLOY  UNS C26000 50/50 Tin-Lead  UNS L55031 BRONZE ALLOY  UNS C41100
ACSS STAINLESS STEEL  UNS S30403 (304L) COPPER ALLOY  UNS C10200 STAINLESS STEEL  UNS S32100
ACNI NICKEL-IRON ALLOY NI 50 (HI PERM 49) COPPER ALLOY  UNS C10200 NICKEL 200 ALLOY  UNS NO2200
       
 
 
 

* All ANDREX hose is pressure tested and the maximum working pressure represents a safe hydrostatic working pressure under non-pulsating heads but because of variables such as temperature and start up pressure peaks, these should be used as general guidelines only, and always check with us for any data that may have changed.